News

Miro: A New Standard in Responsible Innovation

Miro: A New Standard in Responsible Innovation The Miro monitor arm is setting new benchmarks in sustainability. It offers a high-performance solution without compromising on environmental responsibility. Designed with careful material selection, local sourcing, and longevity in mind, Miro’s responsible approach to design and unique manoeuvrability set it apart from the competition. Sustainable Choices Miro is crafted from energy-efficient materials with a lower carbon impact....

Read more
HSE Advisor

Role Purpose Support in the development, implementation and maintenance of the company’s Health, Safety & Environmental policies, processes, operational procedures, and standards.  Ensuring best practice and championing a continually improving HSE culture within the business. Key Responsibilities Liaise with and provide support to all areas of the business to eliminate, mitigate or reduce identified HSE exposures. Partner with the production management team and team leaders,...

Read more
CMD Ltd LAUNCHES 48-HOUR TURNAROUND ON BETATRAK® RAPID ORDERING SERVICE

CMD Ltd, the specialist in power distribution systems, workstation power and monitor arms, has launched a rapid ordering service for its Betatrak® underfloor powertrack distribution systems and accessories, with a commitment to delivering within 48-hours of an approved purchase order*. The service enables customers to order up to 50 lengths of Standard or Clean Earth (C/E) low noise Betatrak, along with up to 25 feed...

Read more
CMD INVESTS £1/4 MILLION IN NEW MACHINE AS PART OF FACTORY UPGRADE

We have invested in a new £1/4m TRUMPF CNC metal punch as part of an asset renewal strategy for our UK manufacturing capability. The new machine will be used in the production of a wide variety of our power distribution systems and workstation power products at our Rotherham factory. Suitable for handling sheet metal between 0.9mm and 3.0mm thick, the new machine will replace one...

Read more
CMD CATALOGUE PROVIDES TECHNICAL POWER DISTRIBUTION GUIDE

CMD Ltd has released a new catalogue, providing an easy to follow technical guide to our power distribution systems and plug and play desk modules. Detailing CMD’s full range of UK-manufactured power distribution systems and plug and play desk modules, the catalogue will be a helpful source of information to M&E engineers and contractors alike to understand how our power distribution systems connect together and...

Read more
Power Distribution Catalogue
CMD Ltd PLAYS ESSENTIAL ROLE IN ELECTRICAL FIT OUT AT LONDON’S PRESTIGIOUS OFFICE DEVELOPMENT

CMD Ltd, specialist in workplace connectivity and ergonomic solutions, has provided a flexible and high-quality power distribution network for The Ray, a prestigious office development in London’s Farringdon. Well-known for being the former site of The Guardian newspaper, The Ray now stands as an 83,000ft² office development characterised by a modernised warehouse aesthetic, with level two now occupied by a global social media company. The...

Read more
The Ray
CMD plugs in to european opportunity with Schuko Capsule unit launch

CMD Ltd, the specialist in power and connectivity solutions for commercial environments, has launched a Schuko version of its popular fixed format Capsule workstation power module for export to mainland Europe and beyond. A popular on desk power module comprising two sockets and dual USB (type A and C) chargers, CMD’s Capsule unit is already widely specified in the UK as an off-the-shelf workstation power...

Read more
CMD White Schuko Capsule Desk Power Module
CMD LTD EXTENDS MONITOR ARM RANGE WITH THE LAUNCH OF REACH PLUS

CMD Ltd, the specialist in ergonomic and connectivity solutions for commercial interiors, has completed its Reach monitor arm range with the launch of the Reach Plus. Available in single or dual screen options, the Reach Plus has been designed to provide an ideal solution for both single and dual screen workstation configurations, or can be used with next generation of large format curved screens. Suitable...

Read more
CMD Ltd DEMONSTRATES THE ART OF POWER DISTRIBUTION AT THE UNIVERSITY OF WARWICK

CMD Ltd, the specialist in workplace connectivity and ergonomic solutions, has provided Betatrak busbar power distribution and a range of electrical accessories for two major capital investment projects at the University of Warwick. Designed by Fielden Clegg Bradley Studios, the £33 million Faculty of Arts building is a showpiece development comprising four interconnected structures set around a central atrium, which will enable inter-disciplinary collaboration across...

Read more
University of Warwick
CMD BRINGS HARMONY TO COVENTRY UNIVERSITY RESEARCH FACILITIES

CMD Ltd, the specialist in power distribution solutions and workstation power and ergonomics, has provided under desk and on desk power modules for the refurbishment of three Coventry University research buildings. Located on Coventry University Technology Park, a business park designed to encourage collaboration between the university and knowledge-based businesses, the three buildings are being repurposed as office accommodation for university research teams. The refurbishment...

Read more
Coventry University

How to Choose PU Sandwich Panels for Your Project?

Choosing PU sandwich panels is not simply a matter of comparing prices or selecting the thickest option. Panel performance depends on insulation needs, building use, climate, fire requirements, and installation quality. A cold-storage facility may require different panels from a workshop, agricultural building, or commercial warehouse.

The right decision begins with the project’s real operating conditions. Measure expected indoor temperatures, humidity, roof loads, wall spans, and cleaning requirements. Then compare core thickness, polyurethane density, steel facings, joint design, thermal conductivity, and documented fire performance. Small details matter. A poorly sealed joint can weaken an otherwise efficient envelope. Water may enter around fasteners, trims, or damaged edges.

Experience also matters during installation. Check whether the supplier provides clear technical data, tested performance, and practical guidance for cutting, lifting, and sealing. Ask for references from similar projects, not only attractive product photographs. Independent test reports can help confirm insulation and fire claims, although laboratory results may not represent every site condition.

No single PU sandwich panels specification suits every building. That assumption causes avoidable problems. A thicker panel may increase cost without solving condensation or structural issues. A cheaper panel may create maintenance concerns later. Review the design with qualified engineers, installers, and local code professionals before ordering. Some recommendations remain uncertain until site exposure, ventilation, and connection details are verified. Good selection is therefore a balance between measured performance, reliable documentation, and lessons learned from actual construction.

How to Choose PU Sandwich Panels for Your Project?

Define PU Sandwich Panels and Their Core Performance Benefits

PU sandwich panels combine two durable facings with a rigid polyurethane foam core. The core is bonded between steel or other approved surfaces during manufacturing. This creates a lightweight building element with continuous insulation and faster installation. Unlike loose-fill systems, the panel arrives as one controlled assembly. Its performance still depends on joints, fixings, thickness, and workmanship.

PU cores commonly achieve thermal conductivity near 0.022–0.028 W/m·K, according to EN 13165 product classifications. Lower conductivity can reduce panel thickness and heat transfer. That matters in warehouses, cold rooms, and agricultural buildings. The UNEP 2023 Global Status Report states that buildings use about 30% of global final energy. Better envelopes can therefore support meaningful energy savings. PU panels also offer low water absorption and consistent factory production. However, they are not automatically fireproof. Their reaction to fire depends on the complete panel system, facings, joints, and tested classification. I would never select a panel from insulation value alone. That shortcut can create expensive problems.

Tips: Compare declared thermal resistance, not only core conductivity. Check tested fire performance for the exact assembly. Review condensation risk with a qualified building professional. Inspect joint details before ordering. A perfect panel can still underperform when installation is rushed. Also question long-term ageing data, recycled content, and end-of-life options. These points are sometimes overlooked.

Assess Project Requirements for Thermal, Structural, and Moisture Control

How to Choose PU Sandwich Panels for Your Project?

Begin with the building’s thermal target, operating temperature, and local climate. The 2024 Global Status Report for Buildings and Construction states that buildings used about 30% of global final energy in 2022. Efficient envelopes therefore matter beyond simple material selection. PU cores commonly provide low thermal conductivity, often near 0.022–0.028 W/m·K under laboratory conditions. However, joints, fasteners, compression, and installation gaps can reduce real performance. Specify the required U-value, then verify it for the complete panel system. Do not rely only on the core’s declared value.

Structural control needs equal attention. Check panel span tables against wind pressure, snow load, seismic movement, maintenance access, and support spacing. A thicker core does not automatically solve structural risk. Facings, connection design, and edge conditions can govern failure. Project engineers should verify calculations under applicable building standards. Field inspections often find loose fixings or unsupported cut edges. Small details matter.

Moisture control starts with drainage, sealed joints, and vapor movement. ASHRAE guidance emphasizes controlling air leakage because transported air can carry substantial moisture into assemblies. Select joint profiles and sealants for the project’s humidity and temperature range. Cold rooms require special attention around penetrations and doors. The specification may look excellent on paper. Site workmanship can still undermine it. Review condensation risk, surface temperatures, and maintenance access before approval.

How to Choose PU Sandwich Panels for Your Project?

Assess project requirements for thermal, structural, and moisture control.

The chart shows the estimated thermal transmittance of PU sandwich panels at common core thicknesses. Values are calculated using a representative PU core thermal conductivity of 0.022 W/m·K and exclude surface resistance, joints, fasteners, and thermal bridges. Thicker panels generally provide better insulation. Final selection should also verify panel load capacity, support spacing, core compressive strength, joint sealing, and moisture exposure conditions.

Thermal control
Lower U-values indicate lower heat transfer. Increasing PU core thickness reduces the calculated U-value.
Structural control
Check span, wind and snow loads, panel deflection, fastener capacity, and tested compressive strength.
Moisture control
Use well-sealed joints, suitable flashings, and a closed-cell PU core appropriate for the project exposure.

Compare Panel Cores, Thicknesses, Facings, and Fire Ratings

Choosing PU sandwich panels starts with the building’s real demands, not a catalogue photograph. Polyurethane cores offer low thermal conductivity and relatively light weight, making them practical for warehouses, cold rooms, and controlled production areas. Thickness matters when temperatures fluctuate. A 50 mm panel may suit a mild internal partition, while a 100 mm or thicker panel can reduce heat loss in refrigerated spaces. I have seen projects overfocus on insulation values and underestimate joint leakage. Measure the joints carefully.

Facings protect the core from moisture, impact, cleaning chemicals, and corrosion. Coated steel is common, but the coating type should match humidity, salt exposure, and washing routines. Smooth facings clean easily, while textured surfaces can hide damage.

Fire performance needs separate attention. Check the complete tested panel system, including joints, seals, fasteners, and installation direction. A core classification alone does not prove the finished wall meets local requirements. Request current test reports and verify the rating with a qualified fire consultant or building authority.

Tips: Compare thermal performance at the expected operating temperature. Review panel thickness beside energy targets, not alone. Inspect samples for flatness, edge protection, and coating consistency. Confirm the manufacturer’s tolerances before ordering. Small gaps become expensive. Leave room for honest review; a cheaper panel may create higher maintenance costs later.

Evaluate Installation Conditions, Compatibility, and Long-Term Durability

Choosing PU sandwich panels starts with the installation environment, not the catalogue image. Check wall or roof dimensions, substrate flatness, access routes, lifting space, and local temperature swings. Moisture matters. A damp substrate can trap condensation behind the panel. Measure indoor humidity where possible, especially in cold rooms, workshops, and food-processing areas. Confirm the required thermal resistance, panel thickness, joint design, and surface finish against the project’s use.

Compatibility deserves a physical check. Panel cores, coatings, sealants, fasteners, flashings, and supporting steel must work together. Ask for technical data, fire classification, allowable spans, corrosion information, and cleaning limits. Do not assume a familiar sealant is safe for every coating. Test a small hidden area first. At corners and penetrations, inspect how the joint closes. Tiny gaps can become visible drafts and water paths after several seasons. Follow local building requirements and qualified installer guidance.

Long-term durability depends heavily on installation quality. Protect edges during unloading, keep panels off wet ground, and repair damaged coatings before exposure. Use correct fastener spacing and avoid crushing the core. Plan inspections after heavy rain, strong winds, or washdown cycles. Look for loose screws, open joints, staining, and corrosion. A panel may meet its rating yet perform poorly when details are rushed. This is where project teams sometimes overestimate the product and underestimate the site. Recheck assumptions before ordering; a small change in humidity, span, or cleaning practice can alter the suitable specification. Good choices leave room for uncertainty.

Select Suppliers by Standards, Specifications, Cost, and Technical Support

How to Choose PU Sandwich Panels for Your Project?

Supplier selection should begin with standards, not attractive prices. Check whether panels meet EN 14509 or ASTM C1289, depending on the project location. Request test reports for thermal conductivity, fire performance, dimensional tolerance, and bond strength. ISO 9001 certification can indicate controlled production, but it does not replace product testing. Ask for batch records and traceable certificates. Missing paperwork is a warning sign.

Specifications Must Match Actual Conditions

Specifications must match the building’s actual conditions. Compare core density, panel thickness, joint design, span limits, and surface coatings. A thicker panel is not automatically better. The right choice depends on indoor temperature, humidity, wind loads, and installation quality.

The UNEP Global Status Report for Buildings and Construction reported that buildings used 34% of global energy in 2022. Better envelope performance can therefore influence operating costs, not just construction costs. Yet predicted savings may fail when joints are poorly sealed.

Compare Total Cost and Supplier Support

Compare total cost over the service life. Include transport, cutting waste, fasteners, maintenance, and replacement risks. The cheapest quotation can become expensive after installation.

It happens.

Technical support deserves equal attention. Reliable suppliers should provide shop drawings, fixing guidance, fire-test interpretation, and responsive answers during installation. The IEA has reported that building operations account for roughly 30% of global final energy use. This supports careful thermal design, but supplier calculations still need independent review. I would also request a sample panel and inspect its edges, coating, and interlock before signing. Small details often expose larger problems.